S88-270
Single Shaft Open Fan and Blower Motor
• Continuous duty, air over
• Shaded pole
• 60Hz
• 1/2" diameter flatted shaft
• Resilient mounting rings included
• 3 thru bolts, 4.42 diameter bolt circle
• Extended thru bolts, shaft end only
Century Motors
BL6414
Diameter: 5";HP: 1/5-1/10;Volts: 115;F/L Amps: 6.50;Phase: Single;Hz: 60;Service Factor: 1.00;RPM: 1050;Speeds: 3;Rot.: CCWLE;Efficiency: 35%;Shaft Diam.: 1/2";Shaft Length: 4-7/8";Bearin ...
S89-770
Single Shaft Open Fan and Blower Motor
Century Motors
BL6412
Diameter: 5";HP: 1/6;Volts: 115;F/L Amps: 5.50;Phase: Single;Hz: 60;Service Factor: 1.00;RPM: 1050;Speeds: 1;Rot.: CCWLE;Efficiency: 35%;Shaft Diam.: 1/2";Shaft Length: 3-5/8";Bearing Typ ...
S89-771
Single Shaft Open Fan and Blower Motor
Century Motors
BL6420
Diameter: 5";HP: 1/6-1/9;Volts: 115;F/L Amps: 5.60;Phase: Single;Hz: 60;Service Factor: 1.00;RPM: 1050;Speeds: 2;Rot.: CCWLE;Efficiency: 35%;Shaft Diam.: 1/2";Shaft Length: 3-5/8";Bearing ...
S81-250
Evergreen® IM Retrofit Blower Motor
Genteq
6005
Diameter: 5-5/8";HP: 1/2-1/5;Volts: 115/208-230;F/L Amps: 4.00;Phase: Single;Hz: 60;Service Factor: NULL;RPM: 1075;Speeds: 5;Rot.: Rev.;Efficiency: 80%;Shaft Diam.: 1/2";Shaft Length: 5"; ...
S81-251
Evergreen® IM Retrofit Blower Motor
Genteq
6010
Diameter: 5-5/8";HP: 1-1/2;Volts: 115/230;F/L Amps: 11.00/6.70;Phase: Single;Hz: 60/50;Service Factor: NULL;RPM: 1075;Speeds: 5;Rot.: CCW/CW;Efficiency: 80%;Shaft Diam.: 1/2";Shaft Length: ...
S87-627
Belt Drive Fan Motor Sleeve bearing motor replacements for furnace blowers, belt driven fans, air coolers and similar applications with moderate torque requirements
US Motors
8000
Diameter: 5-5/8";HP: 1/4;Volts: 115;F/L Amps: 5.30;Phase: 1;Hz: 60;Service Factor: 1.35;RPM: 1725;Speeds: 1;Rot.: Rev.;Efficiency: 51%;Shaft Diam.: 1/2";Shaft Length: 1-1/2";Bearing Type: ...
S87-628
Belt Drive Fan Motor
US Motors
8100
Diameter: 5-5/8";HP: 1/3;Volts: 115;F/L Amps: 6.70;Phase: 1;Hz: 60;Service Factor: 1.35;RPM: 1725;Speeds: 1;Rot.: Rev.;Efficiency: 57%;Shaft Diam.: 1/2";Shaft Length: 1-1/2";Bearing Type: ...
S87-629
Belt Drive Fan Motor Sleeve bearing motor replacements for furnace blowers, belt driven fans, air coolers and similar applications with moderate torque requirements
US Motors
8200
Diameter: 5-5/8";HP: 1/2;Volts: 115;F/L Amps: 8.70;Phase: 1;Hz: 60;Service Factor: 1.25;RPM: 1725;Speeds: 1;Rot.: Rev.;Efficiency: 66%;Shaft Diam.: 1/2";Shaft Length: 1-1/2";Bearing Type: ...
S88-545
3-Speed Blower Motor 48 Frame Permanent Split Capacitor
US Motors
1971
Diameter: 5-5/8";HP: 1/4;Volts: 208-230;F/L Amps: 1.50;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 3;Rot.: Rev.;Efficiency: 59%;Shaft Diam.: 1/2";Shaft Length: 5";Bearing Type: ...
S88-546
3-Speed Blower Motor 48 Frame Permanent Split Capacitor
US Motors
1864
Diameter: 5-5/8";HP: 1/3;Volts: 115;F/L Amps: 5.00;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 3;Rot.: Rev.;Efficiency: 58%;Shaft Diam.: 1/2";Shaft Length: 5";Bearing Type: SAB ...
S88-547
Blower Motor
US Motors
1972
Diameter: 5-5/8";HP: 1/3;Volts: 208-230;F/L Amps: 1.90;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 3;Rot.: Rev.;Efficiency: 65%;Shaft Diam.: 1/2";Shaft Length: 5";Bearing Type: ...
S88-548
Blower Motor Permanent Split Capacitor
US Motors
1865
Diameter: 5-5/8";HP: 1/2;Volts: 115;F/L Amps: 6.50;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 3;Rot.: Rev.;Efficiency: 65%;Shaft Diam.: 1/2";Shaft Length: 4";Bearing Type: SAB ...
S88-549
3-Speed Blower Motor
US Motors
1973
Diameter: 5-5/8";HP: 1/2;Volts: 208-230;F/L Amps: 2.90;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 3;Rot.: Rev.;Efficiency: 69%;Shaft Diam.: 1/2";Shaft Length: 5";Bearing Type: ...
S88-560
3-Speed Blower Motor 48 Frame Permanent Split Capacitor
US Motors
8904
Diameter: 5-5/8";HP: 3/4;Volts: 115;F/L Amps: 9.50;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 3;Rot.: Rev.;Efficiency: 66%;Shaft Diam.: 1/2";Shaft Length: 4";Bearing Type: SAB ...
S89-093
RESCUE® Direct Drive Blower Motor Permanent Split Capacitor
US Motors
5460
Diameter: 5-5/8";HP: 1/2-1/6;Volts: 115;F/L Amps: 7.30;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 4;Rot.: Rev.;Efficiency: 66%;Shaft Diam.: 1/2";Shaft Length: 5";Bearing Type: ...
S89-287
RESCUE® Direct Drive Blower Motor
US Motors
5470
Diameter: 5-5/8";HP: 3/4-1/5;Volts: 115;F/L Amps: 8.10;Phase: 1;Hz: 60;Service Factor: 1.00;RPM: 1075;Speeds: 4;Rot.: Rev.;Efficiency: 71%;Shaft Diam.: 1/2";Shaft Length: 5";Bearing Type: ...
L36-042
Universal Standing Pilot Burner
BASO Gas Products
J999MKA-2
Tip Style: A;
L36-272
Universal Standing Pilot Burner
BASO Gas Products
J999MYA-2
Tip Style: B;
L36-273
Universal Standing Pilot Burner
BASO Gas Products
J999MHA-2
Tip Style: C;
L47-688
Thermocouple
BASO Gas Products
K17AT-18H
Length: 18";
L47-689
Thermocouple
BASO Gas Products
K17AT-24H
Length: 24";
L47-690
Thermocouple
BASO Gas Products
K17AT-30H
Length: 30";
L47-691
Thermocouple
BASO Gas Products
K17AT-36H
Length: 36";
L47-692
Thermocouple
BASO Gas Products
K17AT-48H
Length: 48";
L47-694
Thermocouple
BASO Gas Products
K17AT-72H
Length: 72";
L36-138
Replacement Limit Control
Cam-Stat
L59-3B-A
Element Length: 3";Limit Temp.: 120°F to 250°F;
L36-139
Replacement Limit Control
Cam-Stat
L59-7B-A
Element Length: 7";Limit Temp.: 120°F to 250°F;
L36-152
Combination Fan and Limit Control
Cam-Stat
FAL3C-05TD-120A
Element Length: 3";Limit Temp.: 150°F to 250°F;Fan Off Temp.: 90°F to 120°F;Fan On Diff.: 25°F to 50°F;
L36-819
Combination Fan and Limit Control
Cam-Stat
FAL7C-05TD-120A
Element Length: 7";Limit Temp.: 150°F to 250°F;Fan Off Temp.: 90°F to 120°F;Fan On Diff.: 25°F to 50°F;
L37-342
Combination Fan and Limit Controls with Start Delay
Cam-Stat
FALTS57C-05T-120A
Element Length: 7";Limit Temp.: 150°F to 250°F;Fan Off Temp.: 90°F to 120°F;Fan On Diff.: 50°F;
L36-074
Replacement Generator for Millivolt Applications
Johnstone Supply
G01A-506
Output: 750mV;Length: 36";Replaces: White-Rodgers: G01A-506; Robertshaw: 1950-001;Features: Includes Adapter Sleeve for PG-9 Pilots;
L36-468
Replacement Generator for Millivolt Applications
Johnstone Supply
GO4A-502
Output: 750mV;Length: 36";Replaces: White-Rodgers: G04A-502; Honeywell: Q313A1139; Robertshaw: 1950-001;Features: No Need for a Sleeve or Other Adapting Hardware;
L36-911
Premium Thermocouple
Resideo
Q340A1074
Length: 24";
L36-912
Premium Thermocouple
Resideo
Q340A1090
Length: 36";
L37-020
Premium Thermocouple
Resideo
Q340A1066
Length: 18";
L37-021
Premium Thermocouple
Resideo
Q340A1082
Length: 30";
L37-022
Premium Thermocouple
Resideo
Q340A1108
Length: 48";
L37-432
Dual Standing Pilot Gas Valve
Resideo
VR8200A2132
Volts: 24VAC;BtuH Capacity: 130,000;Opening Style: Standard;Inlet Conn.: 1/2";Outlet Conn.: 1/2";Side Tap: No;
L37-808
Universal Intermittent Pilot Ignition Control
Resideo
S8610U3009
Description: Control Module;
L37-927
Electronic Ignition Gas Valve
Resideo
VR8345M4302
Volts: 24VAC;BtuH Capacity: 300,000;Opening Style: Standard;Inlet Conn.: 3/4";Outlet Conn.: 3/4";
L38-263
Universal Intermittent Pilot Retrofit System
Resideo
Y8610U4001
Gas Type: Natural/LP;BtuH Capacity: 150,000;Inlet Conn.: 1/2";Outlet Conn.: 1/2";
L38-357
Ignitor Burner
Resideo
Q345A1305
Tip Style: A;
L38-358
Ignitor Burner
Resideo
Q345A1313
Tip Style: B;
L38-359
Ignitor Burner
Resideo
Q345A1321
Tip Style: C;
L38-632
Ignitor Flame Rod Assembly
Resideo
Q3400A1024
Application: Ignitor Flame Rod Assembly;
L38-718
SmartValve® System Control
Resideo
SV9501M2528
Application: Intermittent HSI Pilot;Opening Style: Standard;Temp. Range: -40°F to +175°F;Includes: LP Conversion Kit;
L43-886
Universal Integrated Furnace Control
Resideo
S9200U1000
Replaces over 195 furnace controls
Complete set of wiring harnesses for universal compatibility, simplified installation and field-adjustable timings
LED indicators provide system status, performance and diagnostic information0
L44-673
Universal Electronic Fan Timer
Resideo
ST9120U1011
Replaces 44 existing Honeywell Home controls series (ST9120, ST9101, ST9141, and ST9160)
Includes replaceable fuse and DIP switch with selectable heat and cool delay
Integrates control of all combustion blower and circulating fan operations in a gas warm-air appliance
Includes a replaceable fuse and DIP switch with selectable heat and cool delay for added flexibility0
L44-844
Glowfly® Universal Hot Surface Ignitor
Resideo
Q3200U2002 6PK
Lead Length: 15";
L44-845
Glowfly® Universal Hot Surface Ignitor
Resideo
Q3200U1004
Lead Length: 15";
L48-287
Universal Hot Surface Ignition Module
Resideo
S8910U3000
Description: Universal Hot Surface Ignition Module;
L86-050
Fan and Limit Controller
Resideo
L4064B2210
Element Length: 11-1/2";Min. Switch Temp.: -40°F;Max. Switch Temp.: 190°F;Fan On Temp.: 65°F to 215°F;Mounting: Surface;
L86-051
Fan and Limit Controller
Resideo
L4064B2228
Element Length: 5";Min. Switch Temp.: -40°F;Max. Switch Temp.: 190°F;Fan On Temp.: 65°F to 215°F;Mounting: Surface;
L86-052
Fan and Limit Controller
Resideo
L4064B2236
Element Length: 8";Min. Switch Temp.: -40°F;Max. Switch Temp.: 190°F;Fan On Temp.: 65°F to 215°F;Mounting: Surface;
L86-058
Universal Intermittent Pilot Retrofit System
Resideo
Y8610U6006
Gas Type: Natural/LP;BtuH Capacity: 270,000;Inlet Conn.: 1/2";Outlet Conn.: 3/4";
L36-403
700 Series 24V Combination Gas Valve
Robertshaw
700-400
Volts: 24 VAC;BtuH Capacity: 240,000;Inlet Conn.: 1/2";Outlet Conn.: 3/4";Bushings: One 3/4" x 1/2";Side Tap: No;
L37-540
720 Series Dual Valve Control
Robertshaw
720-400
BtuH Capacity: 150,000;Inlet Conn.: 1/2";Outlet Conn.: 3/4";Bushings: One 3/4" x 1/2" , One 1/2" x 3/8", One 3/4" x 3/8";Side Tap: No;
L38-127
Automatic Pilot Re-Light Kit
Robertshaw
785-001
Combination 24VAC or 120VAC module
All hardware included to replace similar type modules
24/117VAC, 0.1A0
L38-693
Hot Surface Ignitor
Supco
SIG101
Lead Length: 10";
L38-694
Hot Surface Ignitor
Supco
SIG102
Lead Length: 6";
L36-075
Replacement Generator for Millivolt Applications
White-Rodgers
G01A-505
Output: 750mV;Length: 36";Replaces: White-Rodgers: G01A-505; Honeywell: Q313A1188; Robertshaw: 1950-532;Features: Mounting Nut & Spring Clip;
L36-983
Standing Pilot Gas Valve
White-Rodgers
36C03-333
Volts: 24VAC;BtuH Capacity: 230,000;Opening Style: Fast;Inlet Conn.: 1/2";Outlet Conn.: 3/4";Side Tap: Yes;
L37-502
Standing Pilot Gas Valve
White-Rodgers
36C03-300
Volts: 24VAC;BtuH Capacity: 230,000;Opening Style: Fast;Inlet Conn.: 1/2";Outlet Conn.: 3/4";Side Tap: No;
L37-698
Silicon Carbide Hot Surface Ignitor
White-Rodgers
767A-369
Lead Length: 5-1/2";
L37-699
Silicon Carbide Hot Surface Ignitor
White-Rodgers
767A-371
Lead Length: 19-1/8";
L37-812
Silicon Carbide Hot Surface Ignitor
White-Rodgers
767A-361
Lead Length: 5-1/4";
L37-813
Silicon Carbide Hot Surface Ignitor
White-Rodgers
767A-374
Lead Length: 11";
L37-814
Silicon Carbide Hot Surface Ignitor
White-Rodgers
767A-376
Lead Length: 4-1/2";
L37-815
Silicon Carbide Hot Surface Ignitor
White-Rodgers
767A-372
Lead Length: 5-1/4";
L37-816
Silicon Carbide Hot Surface Ignitor
White-Rodgers
767A-370
Lead Length: 5-1/4";
L39-565
Universal Non-Integrated HSI Ignition Module
White-Rodgers
50E47-843
Description: Carbide Non-Integrated HSI Furnace Control;
L39-566
Universal Silicon Carbide Integrated Furnace Control
White-Rodgers
50A55-843
Description: Universal Silicon Carbide Integrated Ignition Control;Ignition Trial Time: 4 Seconds;Retries: 2 Times;Prepurge Period: 30 Seconds;
L37-206
Pump Coupler
Bell & Gossett
118723
Description: Coupler Assembly;
L37-207
Pump Coupler
Bell & Gossett
118473
Description: Coupler Assembly;
L37-350
Pump Coupler
Bell & Gossett
118705
Description: Coupler Assembly;
L80-966
Replacement Parts and Accessories
Bell & Gossett
118844LF
Description: Bearing Assembly for Iron Pumps;Application: Series 100 IB, BI, NFI;
L86-074
Booster Pump
Bell & Gossett
106189
Body Type: Iron;Volts: 115;Phase: 1;RPM: 1725;HP: 1/12;Conn.: NPTF;Flange Size: 3/4" 1", 1-1/4", 1-1/2";Wt. Lbs.: 19;GPM @ 0': 38;GPM @ 4': 25;GPM @ 8': 5;
L81-110
AquaPump (Small)
Resideo
PC3F1558IUF00
Body Type: Cast Iron;HP: 1/25;Flange to Flange: 6.5";GPM @ 1': 15;
L86-128
00 Series Cartridge Circulator Pump
Taco
007-F5
Body Type: Cast Iron;Volts: 115;Phase: 1;RPM: 3250;HP: 1/25;Conn.: Flanged;Flange Size: 3/4", 1", 1-1/4", 1-1/2";Flange to Flange: 6-3/8";Wt. Lbs.: 8;GPM @ 1': N/A;GPM @ 3': 20;GPM @ 5': 17 ...
L87-210
00 Series Cartridge Circulator Pump
Taco
007-SF5
Body Type: Stainless Steel;Volts: 115;Phase: 1;RPM: 3250;HP: 1/25;Conn.: Flanged;Flange Size: 3/4", 1", 1-1/4", 1-1/2";Flange to Flange: 6-3/8";Wt. Lbs.: 9;GPM @ 1': N/A;GPM @ 3': 20;GPM @...
L51-232
ecobee Smart Thermostat Premium
ecobee
EB-STATE6P-01
System Application: Conventional, Gas, Oil, Electric, DualFuel, Forced Air HVAC systems;Stages Heat/Cool: Conventional -(2H/2C) Heat Pumps -(4H/2C) 2 stage heat pump + 2 stage AUX / 2 stage cool;Pow ...
L51-923
ecobee Smart Thermostat Lite Pro
ecobee
EB-STATE7P-01
System Application: Conventional, Gas, Oil, Electric, DualFuel, Forced Air HVAC systems;Stages Heat/Cool: Conventional -(2H/2C) Heat Pumps -(4H/2C) 2 stage heat pump + 2 stage AUX / 2 stage cool;Pow ...
L51-906
Google Nest Learning Thermostat (4th gen) - PRO, Polished Silver
Google Nest
GA05560-US
System Application: Gas, Electric, Forced Air, Heat Pump, Radiant, Oil, Hot Water, Solar and Geothermal;Stages Heat/Cool: Up to 3/2;Power Method: 24V Hardwired and Rechargeable Lithium Battery;Term ...
L44-536
Wireless FocusPro® 6000 Kit
Honeywell Home
YTH6320R1001
System Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity;Stages Heat/Cool: Up to 3/2 Heat Pump or Up to 2/2 Conventional;Power Method: Battery;Terminal Design ...
L44-537
Wireless FocusPro® 5000 Kit
Honeywell Home
YTH5320R1000
System Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity;Stages Heat/Cool: Up to 3/2 Heat Pump or Up to 2/2 Conventional;Power Method: Battery;Terminal Design ...
L44-541
Equipment Interface Module for RedLINK™ Wireless FocusPRO®
Honeywell Home
THM5320R1000
Description: Equipment Interface Module (Wireless FocusPRO);Connected: Yes;
L46-667
RedLINK Enabled VisionPRO® 8000 Thermostat
Honeywell Home
TH8110R1008
System Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity;Stages Heat/Cool: 1/1 Heat Pump or Up to 1 /1 Conventional When Used Standalone; Up to 4/2 Heat Pump or ...
L46-668
RedLINK Enabled VisionPRO® 8000 Thermostat
Honeywell Home
TH8320R1003/U
System Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity;Stages Heat/Cool: 3/2 Heat Pump or Up to 2/2 Conventional When Used Standalone; Up to 4/2 Heat Pump or...
L46-669
RedLINK Enabled VisionPRO® 8000 Thermostat
Honeywell Home
TH8321R1001/U
System Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity;Stages Heat/Cool: Up to 3/2 Heat Pump or Up to 2/2 Conventional When Used Standalone; Up to 4/2 Heat Pu ...
L46-671
IAQ Thermostat Prestige® IAQ Kit with RedLink® and EIM
Honeywell Home
YTHX9421R5085WW
System Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity;Stages Heat/Cool: Up to 4/2 Heat Pump or up to 3/2 Conventional;Power Method: Hardwired;Terminal Desi ...
L49-155
T6 Pro Smart Thermostat
Honeywell Home
TH6320WF2003
System Application: Dual Fuel, 24VAC systems; Gas, Oil, Electric Warm Air; Hot water Coil; Gas, Oil, Electric Hydronic; or Steam / Gravity Systems;Stages Heat/Cool: Up to 3/2 Heat Pump and 2/2 Conven ...
L49-156
T6 Pro Smart Thermostat
Honeywell Home
TH6220WF2006
System Application: 24VAC systems; Gas, Oil, Electric Warm Air; Hot water Coil; Gas, Oil, Electric Hydronic; or Steam / Gravity Systems;Stages Heat/Cool: Up to 2/1 Heat Pump or 2/2 Conventional;Powe ...
L49-157
T6 Pro Programmable Thermostat
Honeywell Home
TH6220U2000
System Application: Standard Efficient Gas Forced Air, High Efficacy Gas Forced Air, Oil Forced Air, Electric Forced Air, Hot water Fan Coil, Geothermal Heat Pump, Air to Air Heat Pump, Hot Water Radi ...
L49-158
T6 Pro Programmable Thermostat
Honeywell Home
TH6210U2001
System Application: Standard Efficient Gas Forced Air, High Efficacy Gas Forced Air, Oil Forced Air, Electric Forced Air, Hot water Fan Coil, Geothermal Heat Pump, Air to Air Heat;Stages Heat/Cool: U ...
L51-911
FocusPRO® Programmable Thermostat
Honeywell Home
TH2110U4004/U
System Application: 24 Vac Systems, 750 mv, Gas, Oil, Electric, Radient Hot Water, and Steam; Stages Heat/Cool: 1H/1C; Power Method: Hardwired or Battery; Terminal Designations: R, Rc, C, W, Y, G, O/B, K, L/A; Color: White; Volts: 24VAC; System Switching: Auto, Manual; Dimensions L x W x H: 4.75 x 2.31 x 6.25; Wt. Lbs.: 0.71; Connected: No;
L51-913
FocusPRO® Smart Thermostat
Honeywell Home
TH2110WF4008/U
System Application: 24 Vac Systems; Gas, Oil, Electric, Radient Hot Water, and Steam;Stages Heat/Cool: 1H/1C;Power Method: Hardwired;Terminal Designations: R, Rc, C, W, Y, G, O/B, K, L/A;Color: Wh ...
L45-101
Non-Programmable Thermostat
Pro1 IAQ
T701
System Application: Gas/Electric or Oil/Heat Pump;Stages Heat/Cool: 1/1;Power Method: Hardwired or Battery;Terminal Designations: Rh, Rc, C, Y, W, G, B, O;Description: 4" Blue Display;
L45-102
Programmable Thermostat
Pro1 IAQ
T705
System Application: Gas/Electric or Oil/Heat Pump;Stages Heat/Cool: 1/1;Power Method: Hardwired or Battery;Terminal Designations: Rh, Rc, C, Y, W, G, B, O;Description: 4 sq. inch display;
L45-103
Programmable Thermostat
Pro1 IAQ
T715
System Application: Gas/Electric or Oil;Stages Heat/Cool: 2/2;Power Method: Hardwired or Battery;Terminal Designations: R, C, Y, Y2, W, W2, G;Description: 4 sq. inch display;
L45-106
Non-Programmable Thermostat
Pro1 IAQ
T771
System Application: Gas/Electric or Oil;Stages Heat/Cool: 1/0 or 0/1;Power Method: Hardwired or Battery;Terminal Designations: R, C, W/Y, G;Description: 4" Blue Display;